Stepper motor pulse generator (stepper motor control), can replace the PLC control simple.

Power supply: AC / DC 100-250V 
auxiliary output power: DC12V 100mA (for sensors) 
output signal frequency: 6Hz ~ 9999Hz (duty ratio of 1: 1) 
Power consumption: less than 4W 
NPN open-drain output capacity: 200mA / 30VDC 
input voltage: High Low ≤2V ≥4V 
Dimensions: 72 × 72 × 95 
Total Weight: 230g Input impedance: ≥4.7K 
Environment: Temperature 0 ~ 60C ° Relative humidity ≤85% 
Storage Temperature : -20 ~ 85C ° 
Installation: Snap 

Two open-drain output NPN transistor 
output OUT1 and OUT2 corresponding stepper motor drives connected to CP and DIR terminals (some CW and CCW)  

You can set the output of walking steps, velocity and direction of motion 

can be set multi-count: 0-15 section

Each step count setting range from 0 to 59999 (eg Sd --- 0 setting 10000, indicating the need to walk 10,000 steps a segment 0) 
each pulse output frequency and direction can be set (nFnnnn as 1F5000, said the forward speed of 5000Hz ) 
Output frequency range: 6-9999Hz 
direction: 0 no pulse output (pause time) 
          an output pulse, the forward movement of 
          the second output pulse, reverse movement 

 Multiple input function terminal 

K / P terminals: with the + 12V terminal connections, running, disconnect stop running; 
RESET terminal: When the input signal, the controller is reset to start segment, and the new start running; 
CP1 and CP2 for versatility Terminal: continuous cycle operation, forced to run single-stage trigger the next stage and other functions;

Run mode control:
 RN --- 1 is expressed as a continuous operation mode, successively run through the set so each segment; 
 RN --- 2 is represented as a single segment operating mode, run through a period of pause time, CP2 input control run section;

 rn --- 3: switch control operating modes: RESET terminal non-functional; CP1 has SD --- 0V connection speed and direction 0 segments run, 
       CP2 has SD 0V connection speed and direction --- paragraph 1 run, no connection When stopped, apply to manual switch control 
       system of reciprocal motion; 
 RN --- 4: positive and negative trigger operating mode: RESET 0V connection stops running, disconnect the run; CP1 SD --- 0 trigger control section has 
       the speed and Running direction, CP2 trigger controls the speed and direction have SD --- 1 segment of operation, applied to A, B two 
       limit switches between positive and negative movement;

Control mode:
 CtrL-1 is expressed as CP and DIR control 
 CtrL-2 is expressed as CW and CCW control

Reset terminal input mode:
 rst - 0 expressed as a level reset, active low reset signal starts to evacuate 
 rst - 1 is expressed as a jump edge reset, reset signal transition process from scratch reset (can As the color locate and eliminate the accumulation of errors), 
 rst - 2 is expressed as the next hop edge of the reset, the reset signal from there to the transition process is reset (as color locate and eliminate the accumulation of errors),

cp2 terminal control mode:
 cp2--0 expressed as after a run is complete, there is an input signal, you run the next stage, in the course of the campaign has entered no school; 
 cp2--1 expressed as long as the input signal to the next period of operation in the course of the campaign there is a signal to the next section and pause, waiting for the next pulse input that is run when you enter;

AC-XXX deceleration setting:
 AC-020 represents a step change in frequency for each move 20Hz,

SC - XX down memory location mode:
 SC - on power and memory location, at the next power-up starting from the memory location to run 
 SC - oF no memory blackouts, power-on reset next, running from the origin

 